Adjust the drive unit's final position and tighten all screws. Hurð ehf. 3. Electrical Connection Cable Installation: Connect the cables between the operator and the ECS 950 control box using the "manoeuvring card" located inside the box. Lid Contacts: Ensure contacts for the control box lid are correctly connected. www.iddparts.net 4. Initial Startup and Limit Calibration Manual Positioning: Unhook the door, move it manually to approximately above the ground, and attach it to the operator. Turn on the power. Marking Reference: Mark a reference point above the floor on the door frame. Calibration Mode: on the maneuvering card.
If the door reverses when pressing the down button, check the safety edge circuit or the RPM transmitter for faults. crawford cdm9 950 installation manual top
Installing and setting up a operator with a 950 control system requires a specific sequence of mechanical assembly and electronic limit-setting to ensure safe operation. 1. Mechanical Drive Unit Assembly Adjust the drive unit's final position and tighten